UPGRADE WASTE WATER TREATMENT 2

Description

Upgrade Waste Water Treatment 2

IONEX KA or KB

Self regenerating circuit version

  • closed loop water circuit → no need for fresh water or connection to canalisation!
  • Removal of solids and all heavy metals → waste water regulations can be met!
  • Decrease of chemical oxygen demand
  • For post treatment of etch and galvanic rinse water
  • Lower and upper sump level control switch
  • 2 different standard sizes
  • Special solutions on request
  • Machine is connected to etch-, developer- or PTH-machine
  • Waste water from these plants is collected in the IONEX
  • Tank capacity: max. 110 l (max. 220 l IONEX B)
  • Cleaning capacity: approx. 100 (200 IONEX B) Eurocards or 1000 (2000 IONEX B ) prerinsed Eurocards
  • Water throughput: 10 l/h (15 l/h IONEX B)
  • Consumption of neutralizing agent:: approx. 100ml on 100l waste water
  • 4 cleaning steps:
    • coarse filter
    • active coal micro filter
    • 1 cation exchanger columns to remove heavy metal ions
    • 2 anion exchanger columns for neutralisation
  • Regenerated rinsing water flows into the tank of the pressure unit and is pumped back to the rinsing zones of the tank

Brand

BUNGARD

Reviews

There are no reviews yet.

Be the first to review “UPGRADE WASTE WATER TREATMENT 2”

Your email address will not be published. Required fields are marked *